Excellent image quality for the finest details

Thanks to the high 2 Megapixels (colour) resolution, a strong contrast ratio of 1400:1 and stable brightness of up to 800 cd/m2, the monitor offers excellent image quality. Even the differences between the finest details are shown – regardless of your viewing angle. This is a great advantage if multiple physicians are looking at the screen.

RadiCS + RadiNET Pro
Consistently secure image quality

The optional EIZO RadiCS software to secure image quality enables extensive maintenance and testing of monitors and includes calibration, acceptance and constancy testing, and the archiving of all areas. If you are working on multiple stations, the use of the RadiNET Pro is recommended. This can be used to centrally control the calibration of all monitors, including data history. This saves you a significant amount of time and ensures consistently high image quality across the entire setup. The basic version RadiCS LE is already included with the RadiForce GX, RX, and MX/MS models.

 

Learn more about the RadiCS application classes

Learn more about RadiCS LE software (included in the delivery)

Learn more about RadiCS software (optionally available)

Learn more about RadiNet Pro software (optionally available)

Observe monochrome and colour images on a single monitor

The hybrid gamma PXL functionality automatically differentiates between monochrome and colour images, pixel by pixel. This creates a hybrid display on which each pixel is displayed with the ideal tone value. In turn, this achieves a greater degree of precision and reliability than for conventional planar detection methods.

Hybrid Gamma PXL
The hybrid gamma PXL functionality automatically differentiates between monochrome and colour images, pixel by pixel.

Blur reduction

LCD panels with a high brightness level tend to have more blurry image rendering thanks to over-framing than would be possible in comparison with an acquired exposure. Therefore, EIZO offers blur reduction anchored in monitor hardware. It retrieves details lost in the contours on the screen, meaning that the image is rendered as clearly as possible.

Erklärung Unschärfe Reduzierung

One billion colour tones thanks to 13 bit LUT

Colour rendering is controlled by a 13 bit look-up table (LUT), up to 10 bits of which are available in the DisplayPort connection. This produces a resolution with a maximum of 1 billion colour tones. The rendering characteristic and fine structures required for diagnostics can therefore be precisely identified.

13-Bit-LUT
Without 13 bit LUT
13-Bit-LUT
With 13 bit LUT

Uniform brightness and high colour purity

The monitor shines thanks to its high colour purity and uniform illumination. This is down to the Digital Uniformity Equaliser (DUE), which corrects imbalances automatically, pixel by pixel. Grey and colour tones of radiological and other medical images are correctly rendered over the entire display. This is vital for diagnostics.

Photograph: R&M without DUE
Without DUE
Photograph: R&M with DUE
With DUE

Balanced image quality thanks to an integrated front sensor

The precise calibration of white point and tone value characteristic curve is provided by an integrated front sensor (IFS). This measures the brightness and greyscales and calibrates the monitor autonomously according to the DICOM standard. The sensor works automatically, without restricting the field of vision of the monitor. You can save the costs, time, and effort of maintenance and rely on a consistently balanced image quality. 

Photograph: R&M calibration without IFS
Without IFS
Photograph: R&M calibration with IFS
With IFS

Evolve your image reading: the Work-and-Flow technology

Radiologists face an increasing amount of information on their screens, as modalities become increasingly digitalized. But imaging procedures now no longer need to be so complex, thanks to the unique Work-and-Flow technology from EIZO, featuring new functions developed specially to meet the requirements of radiologists. The RadiForce RX250 and RadiCS-LE software solution enable you to benefit from the Work-and-Flow functions.

Point-and-Focus
Point-and-Focus: easily select the analysis area

The Point-and-Focus function allows you to quickly select and focus on relevant image areas using your mouse or keyboard. By adjusting the brightness and greyscale, you can highlight interesting parts of an image by dimming the surrounding areas.

Multi-monitor solutions without problems

Thanks to the signal input and output, you can link several RadiForce monitors through their DisplayPort interface. This means that you can realise multi-monitor solutions with the greatest of ease – without labourious and excessive cabling.

Daisy-Chain RadiForce Before
Conventional solution: messy cabling
Daisy-Chain RadiForce After
Daisy-chain compatibility via DisplayPort interface: tidied-up cables

Secure image quality thanks to AAPM/Euref/DIN compliance

The display properties, in particular brightness and contrast, are suited to the creation of image rendering systems compliant with DIN 6868-157. The DICOM® GSDF characteristic is already precisely configured in the factory. This means that greyscales are consistent, which is vital for diagnostics.

Overview RadiCS application classes I to VIII

Foto: Bildqualität durch DIN-Konformitaet
Foto: Bildqualität durch DIN-Konformitaet

Ideal design for the diagnostic environment

The thin, black front housing frames are ideal for use in dark environments. They make it easier to concentrate on the display, while the white side frame of the monitor presents a fresh, clean aesthetic.

Extended durations of use thanks to automatic shut down

The monitor has an automatic shut down option for the backlight (backlight saver). This extends the duration of use. Similar to a screen saver, the LEDs turn off when the screen is not being used. 

The backlight saver is part of the RadiCS software.

Presence sensor: Save electricity when you are not in front of the monitor

Thanks to the presence sensor, you can save electricity and help protect the environment. The sensor registers whether someone is sitting in front of the screen or not. As soon as the person leaves the workstation, the monitor turns off automatically. When the person comes back, it turns back on – fully automatically, without touching the mouse or keyboard. It is always ready for use without a waiting period.

Foto: Ohne Präsenzsensor
Foto: Mit Präsenzsensor

FlexStand: ergonomic base

The base allows the monitor to be tilted and turned, as well as operated in landscape or portrait form. The seamless height adjustment starts from the very bottom on the desk. This guarantees optimal ergonomics, regardless of whether you are standing or sitting in front of the screen. Despite its maximum movement possibilities, the FlexStand base always remains completely stable. 

One monitor, many ports

It doesn't get easier than this: You can connect most of your devices, such as PC, laptop or cameras directly to the monitor because the monitor hasa number of different ports. That makes your daily work easier.

Foto: Umgebungslichtsensor
Ambient light sensor supports the constancy test

The sensor integrated in the monitor is used to measure the ambient light and can be used for constancy tests. The prevalent illumination can be determined by the ambient light sensor with the optional RadiCS software.

Foto: Konstante Helligkeit
Constant brightness during operation

A sensor for the backlight permanently determines the luminance of the monitor. The benefit: The defined and calibrated values are rendered exactly just seconds after the monitor is turned on and remain constant during the entire period of use. The sensor is invisibly integrated in the monitor.

Helligkeitsgarantie
Reliable brightness

EIZO is convinced of the quality of its products. The warranty for the monitors, therefore, also covers the brightness stability.

Foto: LED-Hintergrundbeleuchtung
Modern LED backlight

The monitor has a modern LED backlight. This has several advantages over a conventional CCFL tube: the brightness remains uniformly high, electricity consumption is low, and the service life is significantly longer. The LED backlight is also free from mercury, making it environmentally friendly when disposed of.

MED-XN71
For precise diagnoses: EIZO MED-XN71 graphics card

The EIZO MED-XN71 graphics card supports the properties, functions, and settings of the RadiForce RX250 optimally. It enables precise diagnostics and can control several monitors simultaneously. EIZO offers technical support and a warranty service for all graphics cards. Therefore, we recommend using EIZO graphics cards.

Display the specifications of the MED-XN71


Eye-friendly Comfort Light

EIZO offers a brand-new, easy-to-operate comfort light for radiologists who work in dark diagnosis rooms. The soft illuminance in the background of the screen reduces the strain on the eyes that frequently occurs due to constant light-dark changes between bright screens and objects in a dark environment.

learn more about RadiLight

RadiLight, Augenfreundliches Komfort-Licht

Five-year warranty

EIZO grants a five-year warranty. This is possible thanks to the highly developed production process based on a simple principle of success: sophisticated and innovative monitor technology, made from high-end materials.

Go to the warranty overview


Frequently asked questions
What tools does EIZO provide for quality assurance for image display devices in medical applications?

EIZO has developed the RadiCS software specifically for quality assurance for image display devices in the RadiForce range. It offers extensive tests and automatic alignment to guarantee constant and consistent image reproduction on all RadiForce LCD monitors, but also supports screens from other manufacturers. The software automatically executes test images and helps to perform measurements and assessments in accordance with the guidelines in a cost-effective and time-effective manner. For example, measurement results are automatically transferred to the documentation and archived and can be centrally managed using the optional RadiNET Pro software. A calendar with a reminder function ensures timely checks are performed. A suitable measurement device is required to measure the luminance, including veiling luminance. Measured values from various luminance metres are automatically read by RadiCS.

For what regions of the body and what methods or purpose is a RadiForce screen suitable in accordance with DIN 6868-157?

Depending on the body region / methods, different EIZO RadiForce screens are suitable for image display systems in accordance with DIN 6868-157. The EIZO RadiCS quality assurance software is divided into classes I to VIII. The following table shows a classification of suitable screens in this regard.

Note: An acceptance test is necessary for each image display system for an evaluation in accordance with DIN 6868-157.

What is the allocation of body regions / methods in accordance with DIN 6868-157 to RadiCS application classes and what are the minimum requirements for an image display device?

In accordance with DIN 6868-157, different minimum requirements are placed on image display devices depending on the body region / method. The EIZO RadiCS quality assurance software is divided into classes I to VIII. The following table shows a classification of the classes and minimum requirements in this regard.

Note: An acceptance test is necessary for each image display system for an evaluation in accordance with DIN 6868-157.

What does the DIN 6868-157 standard govern?

DIN V 6868-157. This DIN governs the acceptance test and constancy test for image display systems in radiography in order to ensure the necessary image quality.

From where can I obtain the QA guidelines?

From the Federal Ministry for the Environment, Nature Conservation and Nuclear Safety

Other FAQs on your product can be found in our FAQ section.

To the FAQs

Frequently asked questions
What tools does EIZO provide for quality assurance for image display devices in medical applications?

EIZO has developed the RadiCS software specifically for quality assurance for image display devices in the RadiForce range. It offers extensive tests and automatic alignment to guarantee constant and consistent image reproduction on all RadiForce LCD monitors, but also supports screens from other manufacturers. The software automatically executes test images and helps to perform measurements and assessments in accordance with the guidelines in a cost-effective and time-effective manner. For example, measurement results are automatically transferred to the documentation and archived and can be centrally managed using the optional RadiNET Pro software. A calendar with a reminder function ensures timely checks are performed. A suitable measurement device is required to measure the luminance, including veiling luminance. Measured values from various luminance metres are automatically read by RadiCS.

For what regions of the body and what methods or purpose is a RadiForce screen suitable in accordance with DIN 6868-157?

Depending on the body region / methods, different EIZO RadiForce screens are suitable for image display systems in accordance with DIN 6868-157. The EIZO RadiCS quality assurance software is divided into classes I to VIII. The following table shows a classification of suitable screens in this regard.

Note: An acceptance test is necessary for each image display system for an evaluation in accordance with DIN 6868-157.

What is the allocation of body regions / methods in accordance with DIN 6868-157 to RadiCS application classes and what are the minimum requirements for an image display device?

In accordance with DIN 6868-157, different minimum requirements are placed on image display devices depending on the body region / method. The EIZO RadiCS quality assurance software is divided into classes I to VIII. The following table shows a classification of the classes and minimum requirements in this regard.

Note: An acceptance test is necessary for each image display system for an evaluation in accordance with DIN 6868-157.

What does the DIN 6868-157 standard govern?

DIN V 6868-157. This DIN governs the acceptance test and constancy test for image display systems in radiography in order to ensure the necessary image quality.

From where can I obtain the QA guidelines?

From the Federal Ministry for the Environment, Nature Conservation and Nuclear Safety

Other FAQs on your product can be found in our FAQ section.

To the FAQs

Accessories
Accessories